REMOVAL

I - REMOVAL PREPARATION OPERATION

Renault Clio. Expansion valve: Removal - Refitting

WARNING

In order to avoid any refrigerant leaks, do not damage (deform, twist, etc.) the pipe.

WARNING

To prevent moisture from entering the system, place plugs on the cold loop components which are open to the air.

Note: Use blanking plugs for the fuel circuits with part no. 77 01 208 229 or 77 01 476 857 to plug any openings exposed to the open air. They must be clean. Do not use any which have already been used to plug a fuel circuit.

II - OPERATION FOR REMOVAL OF PART CONCERNED

Renault Clio. Expansion valve: Removal - Refitting

WARNING

Do not lose the bolt when removing it: if the bolt falls into the engine compartment, it will generate a noise which will be heard by the customer. The engine will need to be removed in order to recover the bolt.

REFITTING

I - REFITTING PREPARATION OPERATION

WARNING

Do not remove the blanking plugs from each component until the last moment.

Also, do not remove the components from their packaging until they are to be fitted to the vehicle.

Renault Clio. Expansion valve: Removal - Refitting

Renault Clio. Expansion valve: Removal - Refitting

II - REFITTING OPERATION FOR PART CONCERNED

Renault Clio. Expansion valve: Removal - Refitting

Note: Gradually retighten the expansion valve mounting bolts so that the expansion valve is uniformly positioned on the air conditioning pipes.

III - FINAL OPERATION

Renault Clio. Expansion valve: Removal - Refitting

Note: A summary table gives the quantities of refrigerant in the system according to the engine type (see 62A, Air conditioning, Air conditioning: Parts and consumables for the repair, 62A-2).

READ NEXT:

 Evaporator: Removal - Refitting

AIR CONDITIONING or CLIMATE CONTROL Note: The evaporator is supplied already assembled in the distribution unit. (1) REMOVAL OPERATION FOR REMOVAL OF PART CONCERNED Remove the distribution unit (se

 Expansion valve - intermediate pipe connecting pipe at the expansion valve outlet: Removal - Refitting

F4R or K9K or M4R, and AIR CONDITIONING or CLIMATE CONTROL IMPORTANT To avoid all risk of damage to the systems, apply the safety and cleanliness instructions and operation recommendations before car

 Dehydrator reservoir - expansion valve connecting pipe: Removal - Refitting

AIR CONDITIONING or CLIMATE CONTROL IMPORTANT To avoid all risk of damage to the systems, apply the safety and cleanliness instructions and operation recommendations before carrying out any repair:

SEE MORE:

 Rear side door lock: Removal - Refitting

B85 or K85 REMOVAL I - REMOVAL PREPARATION OPERATION Remove the door trim (see Rear side door trim: Removal - Refitting) (MR 393, 72A, Side opening element trim). Unclip the access blanking cover at the locking bolt of the dummy lock. Loosen the locking bolt completely without removing i

 Engine oil level: topping up, filling

Topping up/filling The vehicle must be parked on level ground and the engine should be cold (for instance, before the engine is started up for the first time in the day). Before performing any action in the engine compartment, the ignition must be switched off by pressing

© 2016-2025 Copyright Renault Clio Owners Club