Renault Clio: Solenoid valve assembly pressure sensor: Removal - Refitting
K9K, and JA5

REMOVAL
REMOVAL PREPARATION OPERATION
IMPORTANT
Before any operation on the sequential system,
discharge the accumulator using the Diagnostic
tool.
- To discharge the accumulator, run command
" Discharge pressure accumulator " AC081.
To confirm the pressure drop, read the " Hydraulic
pressure " parameter for the resulting value.
If there is still pressure in the accumulator, re-run the
" Discharge pressure accumulator " command until
the pressure is negligible and will not pose a risk
when the high pressure pipes are removed.
The pressure reading must be close to zero.
- Position the vehicle on a two-post lift (see Vehicle:
Towing and lifting) (MR 392, 02A, Lifting equipment).
- Remove:
- the battery (see Battery: Removal - Refitting)
(MR 392, 80A, Battery),
- the battery tray (see Battery tray: Removal - Refitting)
(MR 392, 80A, Battery),
- the air filter unit (see Air filter unit: Removal - Refitting)
(MR 392, 12A, Fuel mixture).

- Disconnect the solenoid valve unit pressure sensor connector (1).
- Remove the pressure sensor from the solenoid
valve unit (1) using a long socket.
REFITTING
I - REFITTING OPERATION FOR PART
CONCERNED
- Fit the solenoid valve unit pressure sensor.
- Finger tighten the solenoid valve unit pressure sensor.
- Torque tighten the solenoid valve unit pressure
sensor (15 Nm)
- Connect the solenoid valve unit pressure sensor
connector.
II - FINAL OPERATION.
- Refit:
- the air filter unit (see Air filter unit: Removal - Refitting)
(MR 392, 12A, Fuel mixture),
- the battery tray (see Battery tray: Removal - Refitting)
(MR 392, 80A, Battery),
- the battery (see Battery: Removal - Refitting)
(MR 392, 80A, Battery).
- Carry out the necessary programming (see Fault
finding - Replacement of components (MR 394,
21B, Sequential gearbox).
WARNING
After the accumulator has been fully filled (15
seconds after the ignition has been switched on):
the oil is at the MIN mark.
D4F, and JA3

REMOVAL
REMOVAL PREPARATION OPERATION
IMPORTANT
Before any operation on the sequential system,
discharge the accumulator using the Diagnostic
tool.
- To discharge the accumulator, run command
" Discharge pressure accumulator " AC081.
To confirm the pressure drop, read the " Hydraulic
pressure " parameter for the resulting value.
If there is still pressure in the accumulator, re-run the
" Discharge pressure accumulator " command until
the pressure is negligible and will not pose a risk
when the high pressure pipes are removed.
The pressure reading must be close to zero.
- Position the vehicle on a two-post lift (see Vehicle:
Towing and lifting) (MR 392, 02A, Lifting equipment).
- Remove:
- the battery (see Battery: Removal - Refitting)
(MR 392, 80A, Battery),
- the battery tray (see Battery tray: Removal - Refitting)
(MR 392, 80A, Battery).

- Disconnect the solenoid valve unit pressure sensor connector (1).
- Remove the pressure sensor from the solenoid
valve unit (1) using a long socket.
REFITTING
I - REFITTING OPERATION FOR PART
CONCERNED
- Fit the solenoid valve unit pressure sensor.
- Finger tighten the solenoid valve unit pressure sensor.
- Torque tighten the solenoid valve unit pressure
sensor (15 Nm)
- Connect the solenoid valve unit pressure sensor
connector.
II - FINAL OPERATION.
- Refit:
- the battery tray (see Battery tray: Removal - Refitting)
(MR 392, 80A, Battery),
- the battery (see Battery: Removal - Refitting)
(MR 392, 80A, Battery).
- Carry out the necessary programming (see Fault
finding - Replacement of components (MR 394,
21B, Sequential gearbox).
WARNING
After the accumulator has been fully filled (15
seconds after the ignition has been switched on):
the oil is at the MIN mark.
READ NEXT:
D4F, and JA3
REMOVAL
I - REMOVAL PREPARATION OPERATION
IMPORTANT
Before any operation on the sequential system,
discharge the accumulator using the Diagnostic
tool.
To discharge the accumulator, ru
K9K, and JA5
REMOVAL
I - REMOVAL PREPARATION OPERATION
IMPORTANT
Before any operation on the sequential system,
discharge the accumulator using the Diagnostic
tool.
To discharge the accumulator, ru
K9K, and JA5
REMOVAL
I - REMOVAL PREPARATION OPERATION
Position the vehicle on a two-post lift (see Vehicle:
Towing and lifting) (MR 392, 02A, Lifting equipment).
Disconnect the battery (see Batte
SEE MORE:
VERSION WITHOUT ADAPTATION SUPPLEMENT
REMOVAL
I - REMOVAL PREPARATION OPERATION
Remove:
the retaining clips on the driver side dashboard
lower trim,
the driver side dashboard lower trim.
II - OPERATION FOR REMOVAL OF PART
CONCERNED
Disconnect the accelerator pedal potentiometer con
D4F or F4R or K4J or K4M or M4R
IMPORTANT
Wear leaktight gloves (Nitrile type) for this operation.
IMPORTANT
Always wear protective gear (gloves, goggles and
breathing masks).
Note:
Be sure to work in a clean environment so as not to
allow any contamination of the throttle valve.
CLEANING
I - CLEAN
© 2016-2025 Copyright Renault Clio Owners Club