IMPORTANT
Consult the safety and cleanliness advice and operation
recommendations before carrying out any
repair (see 80A, Battery, Battery: Precautions for
the repair, 80A-4).
REMOVAL
I - REMOVAL PR
I - SAFETY
1 - DANGER: RISK FROM ACID LINKED TO
HANDLING
Sulphuric acid is a highly aggressive and toxic substance
which corrodes most metals.
When handling batteries, it is very important to take th
D4F, and 740 or 742 or 764
REMOVAL
I - REMOVAL PREPARATION OPERATION
Disconnect the battery (see Battery: Removal - Refitting).
Remove the air filter unit (see 12A, Fuel mixture, Air filter unit:
Removal - Refitting, 12A-17).
Move the cooling hose away from the engine wiring
harness bracket.
D4F, and 740 or 742 or 764
WARNING
Do not use any product designed to improve the
electrical contact in the injection computer and oxygen
sensor connectors or on the bodies of the oxygen
sensors. Failure to respect this advice prevents
the oxygen sensor from operating correctly and
results in failu