D4F or K9K, and JA3 or JA5
I - SEQUENTIAL GEARBOX
WARNING
If any operation is carried out on the electro-hydraulic
unit, it is essential to clean the unit using a cleaning
product and compressed air.
K9K, and JA5
REMOVAL
I - REMOVAL PREPARATION OPERATION
IMPORTANT
Before any operation on the sequential system,
discharge the accumulator using the Diagnostic
tool.
To discharge the accumulator, ru
K9K, and JA5
REMOVAL
I - REMOVAL PREPARATION OPERATION
Note:
When replacing the electric pump assembly,
always replace the control relay.
IMPORTANT
Before any operation on the sequential system,
disc
IMPORTANT
To avoid all risk of damage to the systems, apply the safety and
cleanliness instructions and operation recommendations before carrying out any
repair (see Engine: Precautions for the repair).
WARNING
It is strictly forbidden to apply any pressure to the
engine oil sump. Damage to the s
K9K, and 750 or 752 or 766 or 768
IMPORTANT
Before carrying out any work on the injection system,
check using the Diagnostic tool :
that the injector rail is not under pressure,
that the fuel temperature is not too high.
It is essential to respect the safety and cleanliness
advice whenever work